Matching Network: 150Watt Impedance - Manual
Download product sheet for MMN 150 with specifications (PDF)
Tel: +44 (0) 1323 639974
Fax: +44 (0) 1323 739654
Product Description for MMN 150
Coaxial Power Systems Ltd manufacture two styles of impedance matching network to link the load to the RF generator. The purpose of the network is to adjust the input impedance of the load to 50 Ohms so that maximum power is transferred from the generator, whose output impedance is 50 Ohms, to the load.
Coaxial Power Systems Ltd. manufacture two types of network - Manual and Automatic
Manual
The manual matching network consists of two adjustable air vane capacitors and a fixed inductor, which are usually arranged as an "L" network. (The arrangement can be simply converted to a "Pi" network if required). Geared drives with vernier dials are used to adjust the capacitors for minimum reflected power as displayed on the generator reflected power meter. When the reflected power is zero, the system is "tuned" and all of the power output of the generator is being fed to the load. Two models, rated at 150W max. or 600W max. are available
Technical Specifications for MMN 150
Download product sheet for MMN 150 with specifications (PDF)