Matching Network: AMN600C - 600Watt Automatic Impedance - Gas - Automatic
Download product sheet for AMN 600C Combined Matching Network (Gas Caps) with specifications (PDF)
Tel: +44 (0) 1323 639974
Fax: +44 (0) 1323 739654
Product Description for AMN 600C Combined Matching Network (Gas Caps)
Coaxial Power Systems Ltd manufacture range of styles of impedance matching network to link the load to the RF generator. The purpose of the network is to adjust the input impedance of the load to 50 Ohms so that maximum power is transferred from the generator, whose output impedance is 50 Ohms, to the load.
Coaxial Power Systems Ltd. manufacture two types of network - Manual and Automatic The matching network consists of two adjustable gas-filled capacitors and a fixed inductor, which are usually arranged as an "L" network. (The arrangement can be simply converted to a "Pi" network if required). Servo-motors are used to adjust the capacitors for minimum reflected power as displayed on the generator reflected power meter. When the reflected power is zero, the system is "tuned" and all of the power output of the generator is being fed to the load.
At the input of the network, a phase and magnitude detector determines the position of the capacitors. This information is used to drive the servo-motors to the positions, which give zero, or minimum reflected power. The matching network is 1/2 rack, 2U high and can be fitted alongside any generator in the Coaxial Power Systems range of low power RF generators.
The position of each variable capacitor is shown on a 3 1/2 digit LED meter. Automatic or Manual mode is switch selectable - in manual mode the servomotors are controlled by spring loaded switches.
The start position of the capacitors can be individually adjusted. When RF power is detected, the capacitors automatically adjust for minimum reflected power. When the RF is turned off, the motors drive the capacitors back to heir original position. The start positions are adjusted using potentiometers accessible via the controller front panel
(Note; If this matching network is used in conjunction with either our RFG617 or RFG627, then the displays are omitted - the capacitor positions are indicated on the RF generator display panel)
Option: Model DCP-1 : Dark Space Bias Voltage Measurement and Control
A probe, installed inside the network, measures the d.c voltage (0 to 1999V) developed across the dark space in plasma applications such as sputtering and reactive ion etching. The voltage is converted to a 0 to 5V signal which can be fed back to the generator control system. The voltage is displayed on the loading capacitor position meter. Includes all necessary cables to link to any generator in the low power range manufactured by Coaxial Power Systems Ltd.
Technical Specifications for AMN 600C Combined Matching Network (Gas Caps)
Download product sheet for AMN 600C Combined Matching Network (Gas Caps) with specifications (PDF)